Vertiq 81-17 110Kv

G28x9.2R

Philadelphia, PA USA | 15m | 2025-03-11 | 26.0 C | 29.77 in Hg | 23.7% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.4 0.1 5 0.01 2.9 10 2.1 180 Continuous
4.0 48.4 0.2 8 0.03 14.1 70 8.7 380 Continuous
6.0 48.4 0.3 14 0.07 28.7 170 12.1 590 Continuous
8.0 48.4 0.5 24 0.12 40.2 330 13.6 800 Continuous
10.0 48.4 0.8 39 0.19 52.5 530 13.7 1010 Continuous
12.0 48.4 1.2 59 0.29 62.1 810 13.6 1220 Continuous
14.0 48.4 1.8 89 0.41 68.1 1160 13.0 1430 Continuous
16.0 48.3 2.6 126 0.54 73.4 1570 12.5 1630 Continuous
18.0 48.3 3.5 169 0.68 77.8 1990 11.8 1840 Continuous
20.0 48.3 4.6 222 0.83 79.8 2460 11.1 2040 Continuous
22.0 48.2 5.9 286 1.00 82.0 2980 10.4 2240 Continuous
24.0 48.2 7.5 360 1.19 83.9 3540 9.8 2430 Continuous
26.0 48.1 9.4 454 1.39 84.6 4200 9.3 2630 Continuous
28.0 48.1 11.4 547 1.59 85.3 4770 8.7 2810 Continuous
30.0 48.0 13.7 658 1.80 86.2 5450 8.3 3000 Continuous
32.0 47.9 16.2 776 2.02 86.8 6080 7.8 3180 Continuous
34.0 47.8 19.1 916 2.26 87.0 6840 7.5 3360 Continuous
36.0 47.7 22.3 1063 2.50 86.9 7570 7.1 3530 Continuous
38.0 47.6 25.9 1233 2.78 87.1 8360 6.8 3690 Continuous
40.0 47.5 29.8 1416 3.04 86.5 9180 6.5 3850 Continuous
42.0 47.4 33.9 1608 3.33 86.8 10020 6.2 4000 Continuous*
44.0 47.3 38.1 1800 3.57 86.3 10770 6.0 4160 Continuous*
46.0 47.1 42.5 2002 3.82 86.2 11540 5.8 4310 Continuous*
48.0 47.0 45.4 2134 4.02 86.1 12100 5.7 4360 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.