Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.5 0.1 4 0.01 3.9 0 0.0 180 Continuous
4.0 48.5 0.2 8 0.03 14.7 60 7.5 380 Continuous
6.0 48.5 0.3 13 0.07 30.1 160 11.9 590 Continuous
8.0 48.5 0.5 24 0.12 41.4 320 13.4 800 Continuous
10.0 48.4 0.8 38 0.19 53.6 530 14.1 1010 Continuous
12.0 48.4 1.2 58 0.27 59.4 780 13.5 1220 Continuous
14.0 48.4 1.7 82 0.36 66.0 1070 13.0 1430 Continuous
16.0 48.4 2.3 112 0.47 71.2 1390 12.4 1640 Continuous
18.0 48.4 3.1 150 0.58 75.0 1800 12.0 1840 Continuous
20.0 48.3 4.1 199 0.72 78.1 2220 11.2 2050 Continuous
22.0 48.3 5.3 257 0.88 80.4 2690 10.5 2250 Continuous
24.0 48.3 6.6 319 1.01 81.0 3130 9.8 2450 Continuous
26.0 48.2 8.2 395 1.18 82.6 3660 9.3 2650 Continuous
28.0 48.2 9.9 479 1.36 84.2 4200 8.8 2840 Continuous
30.0 48.1 12.0 579 1.54 84.5 4830 8.3 3030 Continuous
32.0 48.0 14.3 685 1.73 85.3 5410 7.9 3220 Continuous
34.0 47.9 16.8 806 1.95 86.3 6080 7.5 3400 Continuous
36.0 47.9 19.6 940 2.18 86.9 6810 7.2 3580 Continuous
38.0 47.8 22.7 1084 2.43 88.1 7570 7.0 3750 Continuous
40.0 47.7 26.0 1240 2.64 87.3 8210 6.6 3920 Continuous
42.0 47.6 29.7 1412 2.85 86.4 8960 6.3 4090 Continuous
44.0 47.4 33.3 1579 3.11 87.7 9670 6.1 4250 Continuous
46.0 47.3 37.4 1769 3.33 86.8 10320 5.8 4410 Continuous*
48.0 47.3 39.4 1860 3.45 87.3 10620 5.7 4500 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.