Vertiq 81-17 110Kv

G26x8.5R

Philadelphia, PA USA | 15m | 2025-03-13 | 23.9 C | 30.05 in Hg | 25.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 56.6 0.1 4 0.01 2.4 10 2.4 180 Continuous
4.0 56.6 0.1 7 0.02 12.4 60 8.2 380 Continuous
6.0 56.6 0.2 14 0.05 23.4 150 10.7 590 Continuous
8.0 56.5 0.4 23 0.10 35.4 290 12.5 800 Continuous
10.0 56.5 0.6 36 0.15 45.5 470 13.1 1010 Continuous
12.0 56.5 0.9 53 0.23 54.8 690 13.0 1230 Continuous
14.0 56.5 1.3 74 0.30 61.9 940 12.7 1440 Continuous
16.0 56.5 1.8 103 0.39 65.8 1240 12.0 1650 Continuous
18.0 56.5 2.4 138 0.51 71.2 1580 11.4 1860 Continuous
20.0 56.5 3.2 180 0.62 75.1 1980 11.0 2070 Continuous
22.0 56.4 4.0 227 0.74 77.1 2320 10.2 2270 Continuous
24.0 56.4 5.1 286 0.87 79.0 2790 9.8 2470 Continuous
26.0 56.4 6.3 356 1.03 81.3 3300 9.3 2670 Continuous
28.0 56.3 7.7 433 1.20 83.2 3830 8.8 2870 Continuous
30.0 56.3 9.2 517 1.34 82.9 4340 8.4 3060 Continuous
32.0 56.2 10.9 610 1.52 84.9 4870 8.0 3260 Continuous
34.0 56.2 13.0 729 1.73 85.8 5570 7.6 3450 Continuous
36.0 56.1 14.9 835 1.87 85.6 6060 7.3 3640 Continuous
38.0 56.0 17.3 972 2.11 86.8 6750 6.9 3820 Continuous
40.0 55.9 19.8 1110 2.31 86.8 7410 6.7 3990 Continuous
42.0 55.9 22.4 1253 2.48 86.4 7920 6.3 4170 Continuous
44.0 55.8 25.9 1442 2.77 87.4 8920 6.2 4340 Continuous
46.0 55.7 28.7 1597 2.95 87.2 9470 5.9 4510 Continuous
48.0 55.6 32.2 1786 3.17 86.5 10180 5.7 4660 Continuous
50.0 55.5 35.5 1970 3.39 87.1 10890 5.5 4830 Continuous*
52.0 55.3 39.6 2191 3.66 86.9 11750 5.4 4970 Continuous*
54.0 55.2 43.2 2385 3.86 86.8 12310 5.2 5120 Continuous*
56.0 55.1 45.7 2520 4.02 86.6 12950 5.1 5180 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.