Vertiq 81-08 G2 85Kv

NS30x10R

Philadelphia, PA USA | 15m | 2025-02-05 | 24.5 C | 30.36 in Hg | 20.3% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.0 0.1 4 0.01 3.7 30 8.1 140 Continuous
4.0 48.0 0.1 5 0.03 16.4 80 16.3 300 Continuous
6.0 48.0 0.2 8 0.06 33.8 160 19.8 450 Continuous
8.0 47.9 0.3 14 0.11 49.6 290 21.4 600 Continuous
10.0 47.9 0.5 22 0.17 61.0 450 20.6 750 Continuous
12.0 47.9 0.7 34 0.25 68.3 670 19.6 900 Continuous
14.0 47.9 1.1 51 0.34 73.7 920 18.1 1050 Continuous
16.0 47.9 1.5 72 0.45 77.8 1210 16.8 1200 Continuous
18.0 47.9 2.0 98 0.56 80.3 1540 15.7 1340 Continuous
20.0 47.9 2.7 128 0.68 82.2 1870 14.6 1480 Continuous
22.0 47.8 3.4 163 0.81 83.6 2190 13.5 1610 Continuous
24.0 47.8 4.2 201 0.92 84.0 2510 12.5 1740 Continuous
26.0 47.8 5.1 245 1.07 84.7 2900 11.8 1860 Continuous
28.0 47.8 6.1 291 1.20 84.7 3240 11.1 1970 Continuous
30.0 47.7 7.2 343 1.33 84.4 3640 10.6 2080 Continuous
32.0 47.7 8.2 393 1.45 84.2 3950 10.0 2180 Continuous
34.0 47.7 9.4 449 1.58 84.2 4300 9.6 2290 Continuous
36.0 47.6 10.6 506 1.71 84.1 4690 9.3 2380 Continuous
38.0 47.6 12.1 577 1.84 82.4 5060 8.8 2470 Continuous
40.0 47.5 13.7 650 1.99 81.8 5450 8.4 2550 Continuous
42.0 47.5 15.2 720 2.12 80.9 5760 8.0 2630 Continuous*
44.0 47.4 16.9 803 2.26 79.7 6130 7.6 2700 Continuous*
46.0 47.4 18.7 888 2.39 78.0 6540 7.4 2770 Continuous*
48.0 47.4 20.1 951 2.48 77.0 6790 7.1 2820 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.