Vertiq 81-08 240Kv

P19x5.7

Philadelphia, PA USA | 15m | 2023-04-05 | 24.7 C | 30.2 in Hg | 48.7 %

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 49.9 0.1 4 340 0.00 4.2 10 2.5
4.0 49.9 0.2 9 760 0.02 14.0 50 5.6
6.0 49.8 0.3 17 1190 0.04 26.2 130 7.5
8.0 49.8 0.6 30 1630 0.07 37.5 250 8.2
10.0 49.8 1.0 49 2080 0.11 47.3 430 8.7
12.0 49.8 1.5 75 2540 0.16 55.7 640 8.5
14.0 49.7 2.2 112 3000 0.22 62.1 920 8.2
16.0 49.6 3.3 162 3490 0.30 68.3 1310 8.1
18.0 49.6 4.6 227 3990 0.40 73.0 1740 7.7
20.0 49.4 6.2 308 4480 0.50 76.0 2200 7.1
22.0 49.3 8.5 419 5040 0.62 78.5 2770 6.6
24.0 49.1 11.6 567 5580 0.78 80.7 3500 6.2
26.0 48.8 14.7 718 6080 0.93 82.0 4150 5.8
28.0 48.5 18.0 876 6480 1.07 82.8 4820 5.5
30.0 48.3 21.5 1038 6860 1.21 83.4 5390 5.2
32.0 48.0 24.8 1190 7170 1.33 83.8 5940 5.0
34.0 47.7 28.2 1346 7440 1.45 83.8 6470 4.8
36.0 47.3 31.8 1505 7710 1.56 83.7 6950 4.6
38.0 47.0 35.3 1659 7950 1.66 83.4 7400 4.5
40.0 46.7 39.4 1837 8190 1.77 82.8 7890 4.3
42.0 46.3 43.3 2006 8430 1.86 82.0 8250 4.1
44.0 45.9 48.6 2228 8620 2.00 81.0 8870 4.0
46.0 45.6 49.8 2275 8650 2.02 80.4 8960 3.9

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.