Vertiq 81-08 240Kv

P18x6.1

Philadelphia, PA USA | 15m | 2023-04-05 | 24.4 C | 30.21 in Hg | 49.5 %

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 48.2 0.1 4 340 0.00 2.9 10 2.5
4.0 48.2 0.2 9 760 0.01 12.4 50 5.7
6.0 48.2 0.4 17 1210 0.03 24.2 120 7.1
8.0 48.2 0.6 30 1660 0.06 35.7 240 8.1
10.0 48.2 1.0 48 2120 0.10 46.9 400 8.3
12.0 48.1 1.6 75 2570 0.16 56.0 640 8.5
14.0 48.1 2.3 111 3050 0.22 62.7 930 8.4
16.0 48.0 3.3 157 3520 0.29 68.9 1260 8.0
18.0 47.9 4.7 224 4030 0.39 73.3 1730 7.7
20.0 47.7 6.5 312 4550 0.50 76.9 2250 7.2
22.0 47.5 9.1 432 5140 0.64 79.4 2880 6.7
24.0 47.2 12.4 584 5700 0.80 81.4 3630 6.2
26.0 46.9 15.8 741 6220 0.94 82.5 4270 5.8
28.0 46.5 19.3 896 6610 1.08 83.2 4920 5.5
30.0 46.2 22.9 1058 6970 1.21 83.8 5550 5.2
32.0 45.9 26.2 1200 7270 1.33 84.2 6060 5.0
34.0 45.5 29.3 1336 7550 1.42 84.0 6460 4.8
36.0 45.2 33.0 1492 7800 1.54 84.1 7000 4.7
38.0 44.9 36.5 1639 8070 1.63 83.8 7380 4.5
40.0 44.6 40.8 1820 8260 1.75 83.4 8000 4.4
42.0 44.2 45.0 1991 8490 1.85 82.6 8410 4.2
44.0 44.0 47.1 2071 8580 1.89 82.1 8580 4.1
46.0 43.9 46.9 2058 8540 1.88 81.9 8580 4.2
48.0 43.8 46.8 2050 8510 1.88 81.8 8570 4.2

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.