Vertiq 81-08 G2 240Kv (w/ Rotor Cover)

P17x5.8R

Philadelphia, PA USA | 15m | 2025-03-05 | 25.4 C | 29.76 in Hg | 30.8% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 48.4 0.1 4 370 0.00 2.6 10 2.3
4.0 48.4 0.2 11 850 0.01 10.4 50 4.7
6.0 48.4 0.4 20 1350 0.03 21.1 130 6.4
8.0 48.4 0.7 33 1850 0.05 31.8 250 7.5
10.0 48.4 1.1 52 2340 0.09 42.3 410 7.9
12.0 48.4 1.6 77 2830 0.13 50.8 610 7.9
14.0 48.3 2.3 110 3310 0.19 58.3 850 7.7
16.0 48.3 3.2 152 3790 0.24 63.8 1140 7.5
18.0 48.3 4.2 203 4250 0.31 68.1 1470 7.3
20.0 48.2 5.5 264 4710 0.38 71.8 1830 6.9
22.0 48.2 7.0 335 5160 0.46 74.5 2220 6.6
24.0 48.2 8.7 418 5600 0.55 76.7 2630 6.3
26.0 48.1 10.6 509 6030 0.63 78.2 3050 6.0
28.0 48.0 12.8 616 6410 0.73 79.9 3550 5.8
30.0 47.9 15.4 737 6810 0.83 80.2 4050 5.5
32.0 47.9 17.8 852 7220 0.92 81.6 4480 5.3
34.0 47.8 20.6 986 7600 1.02 81.9 4950 5.0
36.0 47.7 23.8 1136 7940 1.12 82.3 5500 4.8
38.0 47.6 27.2 1293 8280 1.23 82.7 6020 4.7
40.0 47.5 30.4 1446 8590 1.33 82.6 6470 4.5
42.0 47.4 34.2 1623 8890 1.44 82.6 7020 4.3
44.0 47.3 38.0 1797 9190 1.54 82.5 7540 4.2
46.0 47.1 42.3 1996 9430 1.67 82.5 8130 4.1
48.0 47.1 43.8 2062 9560 1.69 82.3 8290 4.0

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.