Vertiq 81-08 G2 140Kv (w/ Rotor Cover)

SR22x6.6

Philadelphia, PA USA | 15m | 2025-02-06 | 23.2 C | 29.83 in Hg | 28.2% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 48.0 0.1 4 250 0.00 3.1 20 5.1
4.0 48.0 0.1 6 520 0.02 13.1 60 9.2
6.0 48.0 0.2 11 790 0.03 26.2 130 11.8
8.0 48.0 0.4 18 1080 0.07 40.7 240 13.2
10.0 48.0 0.6 29 1360 0.11 52.8 410 14.0
12.0 47.9 0.9 45 1650 0.16 62.4 610 13.6
14.0 47.9 1.4 67 1930 0.23 68.5 860 12.9
16.0 47.9 2.0 95 2210 0.30 73.4 1150 12.1
18.0 47.9 2.6 127 2480 0.38 77.6 1460 11.5
20.0 47.8 3.5 168 2750 0.46 78.9 1790 10.7
22.0 47.8 4.5 214 3010 0.55 81.8 2150 10.1
24.0 47.8 5.6 266 3260 0.65 82.7 2490 9.3
26.0 47.7 6.8 324 3500 0.74 83.5 2860 8.8
28.0 47.7 8.1 387 3740 0.83 83.8 3230 8.4
30.0 47.6 9.6 459 3970 0.94 85.1 3680 8.0
32.0 47.6 11.2 533 4190 1.04 85.7 4050 7.6
34.0 47.5 12.8 611 4400 1.13 85.1 4420 7.2
36.0 47.5 14.7 699 4600 1.24 85.8 4850 6.9
38.0 47.4 16.6 790 4800 1.35 85.7 5270 6.7
40.0 47.4 18.7 888 4980 1.45 84.9 5700 6.4
42.0 47.3 20.9 988 5160 1.56 85.4 6090 6.2
44.0 47.3 23.2 1095 5320 1.67 84.8 6530 6.0
46.0 47.2 25.5 1202 5490 1.76 84.4 6900 5.7
48.0 47.2 26.6 1257 5600 1.80 84.2 7050 5.6

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.