Vertiq 81-08 G2 140Kv
NS30x10R
Philadelphia, PA USA | 15m | 2025-02-07 | 24.5 C | 30.05 in Hg | 24.9% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 48.0 | 0.1 | 4 | 0.02 | 11.5 | 40 | 9.3 | 240 | Continuous |
4.0 | 47.9 | 0.2 | 9 | 0.07 | 40.4 | 170 | 19.3 | 490 | Continuous |
6.0 | 47.9 | 0.4 | 21 | 0.16 | 60.5 | 420 | 20.0 | 740 | Continuous |
8.0 | 47.9 | 0.9 | 45 | 0.31 | 72.1 | 810 | 18.1 | 1000 | Continuous |
10.0 | 47.9 | 1.7 | 82 | 0.49 | 77.9 | 1310 | 16.0 | 1250 | Continuous |
12.0 | 47.9 | 2.8 | 133 | 0.69 | 80.9 | 1860 | 14.0 | 1490 | Continuous |
14.0 | 47.8 | 4.2 | 198 | 0.91 | 81.9 | 2470 | 12.4 | 1710 | Continuous |
16.0 | 47.8 | 5.8 | 276 | 1.13 | 81.6 | 3060 | 11.1 | 1910 | Continuous |
18.0 | 47.7 | 7.7 | 367 | 1.36 | 81.3 | 3680 | 10.0 | 2100 | Continuous |
20.0 | 47.6 | 9.9 | 474 | 1.60 | 80.3 | 4310 | 9.1 | 2270 | Continuous |
22.0 | 47.6 | 12.3 | 584 | 1.81 | 78.8 | 4920 | 8.4 | 2430 | Continuous* |
24.0 | 47.5 | 15.0 | 714 | 2.02 | 76.6 | 5500 | 7.7 | 2580 | Continuous* |
26.0 | 47.4 | 18.4 | 874 | 2.28 | 73.9 | 6200 | 7.1 | 2710 | Intermittent |
28.0 | 47.3 | 22.1 | 1046 | 2.49 | 70.5 | 6790 | 6.5 | 2830 | Intermittent |
30.0 | 47.2 | 26.7 | 1258 | 2.70 | 65.9 | 7360 | 5.9 | 2930 | Intermittent |
32.0 | 47.0 | 31.6 | 1484 | 2.89 | 61.7 | 7870 | 5.3 | 3030 | Intermittent |
34.0 | 46.9 | 37.0 | 1734 | 3.05 | 57.3 | 8270 | 4.8 | 3110 | Intermittent |
36.0 | 46.7 | 43.3 | 2021 | 3.21 | 53.6 | 8810 | 4.4 | 3220 | Intermittent |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.