Philadelphia, PA USA | 15m | 2025-02-07 | 24.5 C | 30.05 in Hg | 24.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.0 0.1 4 0.02 11.5 40 9.3 240 Continuous
4.0 47.9 0.2 9 0.07 40.4 170 19.3 490 Continuous
6.0 47.9 0.4 21 0.16 60.5 420 20.0 740 Continuous
8.0 47.9 0.9 45 0.31 72.1 810 18.1 1000 Continuous
10.0 47.9 1.7 82 0.49 77.9 1310 16.0 1250 Continuous
12.0 47.9 2.8 133 0.69 80.9 1860 14.0 1490 Continuous
14.0 47.8 4.2 198 0.91 81.9 2470 12.4 1710 Continuous
16.0 47.8 5.8 276 1.13 81.6 3060 11.1 1910 Continuous
18.0 47.7 7.7 367 1.36 81.3 3680 10.0 2100 Continuous
20.0 47.6 9.9 474 1.60 80.3 4310 9.1 2270 Continuous
22.0 47.6 12.3 584 1.81 78.8 4920 8.4 2430 Continuous*
24.0 47.5 15.0 714 2.02 76.6 5500 7.7 2580 Continuous*
26.0 47.4 18.4 874 2.28 73.9 6200 7.1 2710 Intermittent
28.0 47.3 22.1 1046 2.49 70.5 6790 6.5 2830 Intermittent
30.0 47.2 26.7 1258 2.70 65.9 7360 5.9 2930 Intermittent
32.0 47.0 31.6 1484 2.89 61.7 7870 5.3 3030 Intermittent
34.0 46.9 37.0 1734 3.05 57.3 8270 4.8 3110 Intermittent
36.0 46.7 43.3 2021 3.21 53.6 8810 4.4 3220 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.