Vertiq 60-08 660Kv

P14x4.8R 24V

Philadelphia, PA USA | 15m | | 27.6 C | 30.02 in Hg | 45.8% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 24.2 0.3 6 0.01 19.7 50 8.0 1160 Continuous
4.0 24.2 1.0 24 0.04 44.8 220 9.0 2500 Continuous
6.0 24.1 2.6 63 0.10 62.6 560 8.9 3820 Continuous
8.0 24.1 5.5 131 0.18 72.2 1030 7.8 5110 Continuous
10.0 24.0 9.8 235 0.28 78.3 1640 7.0 6370 Continuous
12.0 23.8 15.9 378 0.39 81.2 2330 6.2 7580 Continuous
14.0 23.6 24.3 574 0.52 82.9 3160 5.5 8710 Continuous
16.0 23.4 35.1 820 0.67 83.5 4030 4.9 9790 Continuous
18.0 23.0 48.2 1111 0.82 83.2 4930 4.4 10770 Continuous
20.0 22.7 63.7 1442 0.98 82.5 5820 4.0 11650 Continuous*
22.0 22.3 77.0 1718 1.09 81.3 6480 3.8 12230 Continuous*
24.0 22.3 76.8 1712 1.09 81.4 6480 3.8 12210 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.