Vertiq 60-08 660Kv

P13x4.4R 24V

Philadelphia, PA USA | 15m | | 28.1 C | 30.0 in Hg | 48.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 24.2 0.3 6 0.01 14.9 30 4.9 1170 Continuous
4.0 24.1 0.9 22 0.03 37.2 150 6.9 2510 Continuous
6.0 24.1 2.2 53 0.07 54.3 390 7.4 3840 Continuous
8.0 24.1 4.3 103 0.12 65.1 700 6.8 5150 Continuous
10.0 24.0 7.6 181 0.19 71.4 1140 6.3 6430 Continuous
12.0 23.9 12.1 288 0.27 75.8 1650 5.7 7690 Continuous
14.0 23.7 18.2 432 0.36 78.1 2240 5.2 8900 Continuous
16.0 23.6 26.4 621 0.47 79.7 2920 4.7 10060 Continuous
18.0 23.3 36.4 849 0.58 80.2 3630 4.3 11170 Continuous
20.0 23.0 48.6 1120 0.70 79.9 4370 3.9 12180 Continuous
22.0 22.7 62.7 1422 0.82 79.5 5140 3.6 13100 Continuous
24.0 22.7 62.6 1418 0.82 79.1 5080 3.6 13110 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.