Vertiq 60-08 300Kv
24x7.2R 24V
Philadelphia, PA USA | 15m | 2024-08-09 | 26.0 C | 29.79 in Hg | 50.9% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 24.2 | 0.1 | 3 | 0.02 | 36.8 | 60 | 19.1 | 490 | Continuous |
4.0 | 24.2 | 0.6 | 15 | 0.09 | 67.2 | 280 | 18.9 | 1040 | Continuous |
6.0 | 24.1 | 1.9 | 45 | 0.21 | 78.9 | 680 | 15.2 | 1590 | Continuous |
8.0 | 24.1 | 4.2 | 101 | 0.38 | 82.3 | 1270 | 12.6 | 2100 | Continuous |
10.0 | 24.0 | 7.7 | 185 | 0.57 | 82.9 | 1960 | 10.6 | 2570 | Continuous |
12.0 | 23.9 | 12.2 | 293 | 0.77 | 82.3 | 2680 | 9.2 | 2990 | Continuous |
14.0 | 23.8 | 18.0 | 428 | 0.98 | 80.4 | 3430 | 8.0 | 3360 | Continuous |
16.0 | 23.6 | 24.5 | 579 | 1.18 | 78.6 | 4150 | 7.2 | 3690 | Continuous* |
18.0 | 23.4 | 32.3 | 758 | 1.37 | 75.1 | 4830 | 6.4 | 3980 | Intermittent |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.