Vertiq 60-08 300Kv

24x7.2R 24V

Philadelphia, PA USA | 15m | | 26.0 C | 29.79 in Hg | 50.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W)
2.0 24.2 0.1 3 490 0.02 36.8 60 19.1
4.0 24.2 0.6 15 1040 0.09 67.2 280 18.9
6.0 24.1 1.9 45 1590 0.21 78.9 680 15.2
8.0 24.1 4.2 101 2100 0.38 82.3 1270 12.6
10.0 24.0 7.7 185 2570 0.57 82.9 1960 10.6
12.0 23.9 12.2 293 2990 0.77 82.3 2680 9.2
14.0 23.8 18.0 428 3360 0.98 80.4 3430 8.0

Published data is rated for continuous thrust at Normal Temperature and Pressure.
Performance is degraded at higher temperatures and lower pressures.
Performance may exceed published data temporarily, but cannot be sustained continuously.