Vertiq 60-08 300Kv

P18x6.1R 48V

Philadelphia, PA USA | 15m | 2024-08-09 | 26.1 C | 29.79 in Hg | 48.0% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.4 0.1 3 0.01 9.6 20 5.8 470 Continuous
4.0 48.4 0.2 8 0.03 31.9 100 11.8 1020 Continuous
6.0 48.4 0.4 20 0.06 51.4 250 12.4 1610 Continuous
8.0 48.3 0.9 41 0.12 64.8 510 12.3 2190 Continuous
10.0 48.3 1.5 75 0.19 73.1 840 11.3 2760 Continuous
12.0 48.3 2.5 121 0.27 77.6 1240 10.3 3310 Continuous
14.0 48.3 3.8 184 0.36 79.5 1700 9.2 3840 Continuous
16.0 48.2 5.5 265 0.46 79.8 2180 8.2 4350 Continuous
18.0 48.1 7.2 348 0.57 83.5 2700 7.8 4830 Continuous
20.0 48.1 9.6 463 0.69 82.8 3260 7.0 5280 Continuous
22.0 48.0 12.1 581 0.81 83.4 3820 6.6 5710 Continuous
24.0 47.9 15.0 717 0.93 83.0 4380 6.1 6100 Continuous
26.0 47.8 18.0 862 1.05 82.4 4930 5.7 6460 Continuous*
28.0 47.7 21.3 1019 1.17 81.8 5480 5.4 6790 Continuous*
30.0 47.6 24.9 1188 1.29 80.5 6010 5.1 7110 Continuous*
32.0 47.5 28.9 1373 1.40 79.0 6510 4.7 7390 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.