Vertiq 60-08 300Kv
P18x6.1R 24V
Philadelphia, PA USA | 15m | 2024-08-09 | 26.1 C | 29.78 in Hg | 48.9% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 24.2 | 0.1 | 2 | 0.01 | 13.9 | 10 | 4.0 | 510 | Continuous |
4.0 | 24.2 | 0.3 | 7 | 0.03 | 40.4 | 90 | 12.1 | 1080 | Continuous |
6.0 | 24.2 | 0.8 | 19 | 0.06 | 59.1 | 240 | 12.9 | 1670 | Continuous |
8.0 | 24.1 | 1.6 | 40 | 0.12 | 70.5 | 490 | 12.3 | 2240 | Continuous |
10.0 | 24.1 | 3.0 | 72 | 0.19 | 76.2 | 810 | 11.2 | 2800 | Continuous |
12.0 | 24.1 | 5.0 | 119 | 0.27 | 79.8 | 1210 | 10.1 | 3350 | Continuous |
14.0 | 24.0 | 7.5 | 181 | 0.36 | 82.0 | 1650 | 9.1 | 3880 | Continuous |
16.0 | 23.9 | 10.8 | 258 | 0.47 | 83.2 | 2140 | 8.3 | 4390 | Continuous |
18.0 | 23.9 | 14.7 | 350 | 0.58 | 83.8 | 2670 | 7.6 | 4870 | Continuous |
20.0 | 23.7 | 19.4 | 461 | 0.70 | 84.3 | 3220 | 7.0 | 5320 | Continuous |
22.0 | 23.6 | 24.6 | 581 | 0.82 | 84.6 | 3780 | 6.5 | 5750 | Continuous |
24.0 | 23.5 | 28.4 | 669 | 0.89 | 84.0 | 4130 | 6.2 | 6000 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.