Vertiq 60-08 300Kv

P18x6.1R 24V

Philadelphia, PA USA | 15m | 2024-08-09 | 26.1 C | 29.78 in Hg | 48.9% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 24.2 0.1 2 0.01 13.9 10 4.0 510 Continuous
4.0 24.2 0.3 7 0.03 40.4 90 12.1 1080 Continuous
6.0 24.2 0.8 19 0.06 59.1 240 12.9 1670 Continuous
8.0 24.1 1.6 40 0.12 70.5 490 12.3 2240 Continuous
10.0 24.1 3.0 72 0.19 76.2 810 11.2 2800 Continuous
12.0 24.1 5.0 119 0.27 79.8 1210 10.1 3350 Continuous
14.0 24.0 7.5 181 0.36 82.0 1650 9.1 3880 Continuous
16.0 23.9 10.8 258 0.47 83.2 2140 8.3 4390 Continuous
18.0 23.9 14.7 350 0.58 83.8 2670 7.6 4870 Continuous
20.0 23.7 19.4 461 0.70 84.3 3220 7.0 5320 Continuous
22.0 23.6 24.6 581 0.82 84.6 3780 6.5 5750 Continuous
24.0 23.5 28.4 669 0.89 84.0 4130 6.2 6000 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.