Vertiq 60-08 300Kv

P17x5.8R 48V

Philadelphia, PA USA | 15m | 2024-08-09 | 26.2 C | 29.77 in Hg | 58.1% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.3 0.1 3 0.00 7.9 10 3.3 480 Continuous
4.0 48.3 0.2 7 0.02 26.6 70 9.5 1030 Continuous
6.0 48.3 0.3 16 0.04 45.7 180 11.0 1620 Continuous
8.0 48.3 0.7 31 0.08 58.9 350 11.1 2210 Continuous
10.0 48.3 1.2 56 0.13 69.2 590 10.6 2790 Continuous
12.0 48.3 1.9 91 0.19 74.5 900 9.8 3360 Continuous
14.0 48.3 2.9 140 0.26 76.8 1240 8.9 3920 Continuous
16.0 48.2 4.2 201 0.34 79.7 1650 8.2 4450 Continuous
18.0 48.2 5.6 271 0.43 82.8 2090 7.7 4970 Continuous
20.0 48.1 7.4 357 0.52 83.2 2540 7.1 5470 Continuous
22.0 48.1 9.5 458 0.62 84.0 3030 6.6 5940 Continuous
24.0 48.0 11.8 568 0.72 84.6 3530 6.2 6390 Continuous
26.0 47.9 14.4 689 0.82 84.9 4020 5.8 6820 Continuous
28.0 47.9 17.2 823 0.92 84.3 4520 5.5 7220 Continuous
30.0 47.8 20.3 969 1.03 84.2 5050 5.2 7580 Continuous
32.0 47.7 23.5 1120 1.13 83.6 5530 4.9 7940 Continuous*
34.0 47.6 27.0 1284 1.23 82.9 6010 4.7 8270 Continuous*
36.0 47.5 30.6 1453 1.32 81.8 6460 4.4 8580 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.