Philadelphia, PA USA | 15m | 2024-08-09 | 25.9 C | 29.77 in Hg | 57.6% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 24.2 0.1 2 0.01 15.1 20 9.4 510 Continuous
4.0 24.2 0.3 7 0.02 36.9 90 13.7 1090 Continuous
6.0 24.2 0.6 15 0.05 55.0 200 13.1 1680 Continuous
8.0 24.2 1.2 30 0.08 65.5 370 12.3 2260 Continuous
10.0 24.1 2.2 53 0.13 74.8 610 11.4 2840 Continuous
12.0 24.1 3.7 89 0.20 80.2 930 10.5 3400 Continuous
14.0 24.1 5.6 135 0.27 83.0 1290 9.6 3950 Continuous
16.0 24.0 8.1 195 0.36 86.4 1740 8.9 4490 Continuous
18.0 23.9 11.1 266 0.44 87.2 2180 8.2 5000 Continuous
20.0 23.9 14.7 351 0.53 87.9 2640 7.5 5510 Continuous
22.0 23.8 19.0 451 0.63 88.2 3140 7.0 5980 Continuous
24.0 23.7 22.5 532 0.71 87.8 3500 6.6 6320 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.