Vertiq 60-08 300Kv

P16x5.4R 48V

Philadelphia, PA USA | 15m | 2024-08-09 | 25.9 C | 29.77 in Hg | 50.4% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.4 0.1 3 0.00 7.7 10 3.4 480 Continuous
4.0 48.3 0.1 7 0.02 24.4 60 8.5 1030 Continuous
6.0 48.3 0.3 15 0.04 41.8 140 9.5 1630 Continuous
8.0 48.3 0.6 28 0.07 56.0 270 9.8 2220 Continuous
10.0 48.3 1.0 48 0.11 65.6 460 9.6 2810 Continuous
12.0 48.3 1.6 76 0.15 71.6 690 9.1 3380 Continuous
14.0 48.3 2.4 115 0.21 76.3 990 8.6 3950 Continuous
16.0 48.2 3.4 162 0.27 79.6 1310 8.1 4500 Continuous
18.0 48.2 4.6 222 0.34 81.6 1680 7.6 5040 Continuous
20.0 48.2 6.0 289 0.42 84.2 2050 7.1 5560 Continuous
22.0 48.1 7.9 383 0.50 83.3 2500 6.5 6060 Continuous
24.0 48.1 9.9 474 0.59 84.8 2920 6.2 6550 Continuous
26.0 48.0 12.1 579 0.67 85.0 3360 5.8 7010 Continuous
28.0 47.9 14.6 700 0.77 85.3 3860 5.5 7440 Continuous
30.0 47.9 17.2 825 0.85 85.0 4270 5.2 7870 Continuous
32.0 47.8 20.2 965 0.95 85.0 4750 4.9 8250 Continuous
34.0 47.7 23.2 1109 1.04 84.6 5190 4.7 8620 Continuous
36.0 47.6 26.5 1264 1.13 84.1 5640 4.5 8970 Continuous*
38.0 47.5 30.1 1432 1.23 83.3 6100 4.3 9290 Continuous*
40.0 47.4 33.7 1597 1.31 82.2 6490 4.1 9590 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.