Vertiq 60-08 300Kv

P16x5.4R 24V

Philadelphia, PA USA | 15m | 2024-08-09 | 26.1 C | 29.77 in Hg | 51.1% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 24.2 0.1 2 0.00 9.0 10 4.5 510 Continuous
4.0 24.2 0.2 6 0.01 27.7 40 6.8 1090 Continuous
6.0 24.2 0.5 13 0.03 45.5 130 9.9 1680 Continuous
8.0 24.2 1.1 26 0.06 57.8 260 10.1 2270 Continuous
10.0 24.1 1.9 45 0.10 66.2 450 10.0 2850 Continuous
12.0 24.1 3.1 74 0.15 72.2 710 9.6 3420 Continuous
14.0 24.1 4.6 111 0.20 75.6 990 8.9 3980 Continuous
16.0 24.0 6.6 159 0.26 78.3 1330 8.4 4530 Continuous
18.0 24.0 9.1 217 0.33 80.4 1680 7.7 5070 Continuous
20.0 23.9 12.2 291 0.41 82.4 2110 7.2 5590 Continuous
22.0 23.8 15.7 374 0.49 83.1 2520 6.7 6090 Continuous
24.0 23.8 19.0 451 0.56 84.1 2870 6.4 6490 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.