Vertiq 60-08 300Kv

P15x5R 48V

Philadelphia, PA USA | 15m | 2024-08-09 | 25.9 C | 29.78 in Hg | 49.2% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.3 0.1 3 0.00 4.1 10 3.3 490 Continuous
4.0 48.3 0.1 7 0.01 17.0 50 7.7 1040 Continuous
6.0 48.3 0.3 13 0.02 32.0 120 9.3 1640 Continuous
8.0 48.3 0.5 23 0.04 44.8 230 10.0 2230 Continuous
10.0 48.3 0.8 38 0.07 55.4 370 9.7 2820 Continuous
12.0 48.3 1.2 60 0.11 63.2 570 9.5 3410 Continuous
14.0 48.3 1.8 89 0.15 69.8 810 9.1 3980 Continuous
16.0 48.3 2.6 124 0.20 75.4 1080 8.7 4550 Continuous
18.0 48.2 3.7 181 0.25 74.0 1390 7.7 5110 Continuous
20.0 48.2 4.7 226 0.30 79.8 1690 7.5 5660 Continuous
22.0 48.2 6.2 298 0.37 81.1 2080 7.0 6190 Continuous
24.0 48.1 7.7 373 0.43 82.0 2420 6.5 6710 Continuous
26.0 48.1 9.5 457 0.50 83.0 2810 6.1 7210 Continuous
28.0 48.0 11.6 555 0.58 83.5 3220 5.8 7700 Continuous
30.0 48.0 13.9 665 0.66 84.2 3680 5.5 8160 Continuous
32.0 47.9 16.3 781 0.73 84.4 4100 5.3 8600 Continuous
34.0 47.8 19.0 907 0.81 84.6 4540 5.0 9040 Continuous
36.0 47.7 21.8 1038 0.89 84.5 4960 4.8 9450 Continuous
38.0 47.7 24.8 1180 0.96 84.3 5390 4.6 9840 Continuous
40.0 47.6 28.0 1331 1.05 84.2 5850 4.4 10190 Continuous*
42.0 47.5 31.3 1488 1.13 83.7 6290 4.2 10540 Continuous*
44.0 47.4 34.8 1648 1.20 83.3 6680 4.1 10880 Continuous*
46.0 47.3 38.6 1825 1.28 82.5 7080 3.9 11190 Continuous*
48.0 47.2 40.2 1898 1.31 81.9 7190 3.8 11320 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.