Vertiq 60-08 150Kv

SRZ 20x6R

Philadelphia, PA USA | 15m | 27.3 C | 29.95 in Hg | 41.0% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 48.2 0.0 2 0.01 10.6 10 5.2 270 Continuous
4.0 48.2 0.1 3 0.02 27.9 40 12.8 540 Continuous
6.0 48.2 0.1 6 0.03 43.9 100 17.2 810 Continuous
8.0 48.2 0.2 10 0.05 55.4 180 17.4 1090 Continuous
10.0 48.2 0.3 17 0.08 64.2 280 16.6 1370 Continuous
12.0 48.2 0.5 26 0.11 71.2 410 15.5 1650 Continuous
14.0 48.2 0.8 40 0.15 75.2 580 14.4 1930 Continuous
16.0 48.2 1.2 57 0.20 79.2 780 13.6 2200 Continuous
18.0 48.1 1.6 77 0.24 81.9 960 12.5 2480 Continuous
20.0 48.1 2.1 103 0.30 83.8 1220 11.9 2740 Continuous
22.0 48.1 2.8 132 0.36 84.8 1460 11.0 3000 Continuous
24.0 48.1 3.5 166 0.42 86.1 1740 10.5 3260 Continuous
26.0 48.1 4.3 206 0.48 86.4 2030 9.8 3510 Continuous
28.0 48.0 5.2 250 0.55 86.8 2310 9.3 3750 Continuous
30.0 48.0 6.3 302 0.63 87.0 2670 8.8 3980 Continuous
32.0 48.0 7.4 353 0.70 87.1 2960 8.4 4210 Continuous
34.0 48.0 8.5 410 0.77 87.2 3270 8.0 4430 Continuous
36.0 47.9 9.9 475 0.85 87.0 3610 7.6 4630 Continuous
38.0 47.9 11.2 537 0.92 86.7 3920 7.3 4840 Continuous
40.0 47.8 12.7 606 0.99 86.4 4220 7.0 5030 Continuous
42.0 47.8 14.3 682 1.07 85.8 4560 6.7 5210 Continuous*
44.0 47.8 15.9 762 1.15 85.2 4900 6.4 5380 Continuous*
46.0 47.7 17.5 835 1.21 84.5 5130 6.1 5560 Continuous*
48.0 47.7 18.9 903 1.27 83.9 5370 5.9 5700 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.