Vertiq 40-06 770Kv
P13x4.4R
Philadelphia, PA USA | 15m | 2024-06-26 | 23.9 C | 29.73 in Hg | 50.7% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 23.9 | 0.2 | 4 | 0.01 | 41.5 | 60 | 15.7 | 1440 | Continuous |
4.0 | 23.9 | 0.7 | 17 | 0.04 | 72.3 | 220 | 12.7 | 2900 | Continuous |
6.0 | 23.9 | 2.0 | 48 | 0.09 | 83.0 | 490 | 10.2 | 4250 | Continuous |
8.0 | 23.8 | 4.1 | 98 | 0.15 | 85.3 | 820 | 8.4 | 5460 | Continuous |
10.0 | 23.8 | 6.8 | 161 | 0.20 | 85.7 | 1150 | 7.1 | 6490 | Continuous |
12.0 | 23.7 | 10.1 | 239 | 0.26 | 84.6 | 1490 | 6.2 | 7360 | Continuous |
14.0 | 23.4 | 13.9 | 325 | 0.32 | 82.8 | 1810 | 5.6 | 8100 | Continuous |
16.0 | 23.2 | 18.2 | 423 | 0.37 | 80.1 | 2110 | 5.0 | 8740 | Continuous* |
18.0 | 23.1 | 23.3 | 537 | 0.42 | 76.0 | 2400 | 4.5 | 9290 | Intermittent |
20.0 | 22.8 | 29.6 | 676 | 0.46 | 70.3 | 2660 | 3.9 | 9760 | Intermittent |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.