Vertiq 40-06 770Kv

APC 9x4.5R

Philadelphia, PA USA | 15m | 2024-07-18 | 25.1 C | 29.93 in Hg | 53.8% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) Speed (RPM) State of Operation
2.0 23.9 0.1 3 0.00 17.0 20 7.4 1460 Continuous
4.0 23.9 0.4 9 0.01 43.9 70 8.1 2990 Continuous
6.0 23.9 0.9 21 0.03 63.7 170 8.1 4480 Continuous
8.0 23.8 1.8 43 0.05 74.8 320 7.5 5940 Continuous
10.0 23.8 3.2 76 0.08 79.7 500 6.6 7330 Continuous
12.0 23.7 5.2 124 0.11 82.7 710 5.7 8620 Continuous
14.0 23.6 7.8 183 0.15 84.0 930 5.1 9780 Continuous
16.0 23.4 10.9 255 0.19 84.0 1170 4.6 10800 Continuous
18.0 23.3 14.4 334 0.23 83.6 1380 4.1 11680 Continuous
20.0 23.1 18.2 420 0.27 82.8 1600 3.8 12460 Continuous
22.0 22.9 22.3 511 0.30 81.8 1810 3.5 13140 Continuous
24.0 22.9 22.4 512 0.30 81.7 1810 3.5 13140 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.