Vertiq 40-06 770Kv
APC 9x4.5R
Philadelphia, PA USA | 15m | 2024-07-18 | 25.1 C | 29.93 in Hg | 53.8% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 23.9 | 0.1 | 3 | 0.00 | 17.0 | 20 | 7.4 | 1460 | Continuous |
4.0 | 23.9 | 0.4 | 9 | 0.01 | 43.9 | 70 | 8.1 | 2990 | Continuous |
6.0 | 23.9 | 0.9 | 21 | 0.03 | 63.7 | 170 | 8.1 | 4480 | Continuous |
8.0 | 23.8 | 1.8 | 43 | 0.05 | 74.8 | 320 | 7.5 | 5940 | Continuous |
10.0 | 23.8 | 3.2 | 76 | 0.08 | 79.7 | 500 | 6.6 | 7330 | Continuous |
12.0 | 23.7 | 5.2 | 124 | 0.11 | 82.7 | 710 | 5.7 | 8620 | Continuous |
14.0 | 23.6 | 7.8 | 183 | 0.15 | 84.0 | 930 | 5.1 | 9780 | Continuous |
16.0 | 23.4 | 10.9 | 255 | 0.19 | 84.0 | 1170 | 4.6 | 10800 | Continuous |
18.0 | 23.3 | 14.4 | 334 | 0.23 | 83.6 | 1380 | 4.1 | 11680 | Continuous |
20.0 | 23.1 | 18.2 | 420 | 0.27 | 82.8 | 1600 | 3.8 | 12460 | Continuous |
22.0 | 22.9 | 22.3 | 511 | 0.30 | 81.8 | 1810 | 3.5 | 13140 | Continuous |
24.0 | 22.9 | 22.4 | 512 | 0.30 | 81.7 | 1810 | 3.5 | 13140 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.