Vertiq 40-06 770Kv
8x4R
Philadelphia, PA USA | 15m | 2024-07-18 | 25.5 C | 29.93 in Hg | 53.2% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | Speed (RPM) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 23.9 | 0.1 | 3 | 0.00 | 9.7 | 10 | 3.9 | 1460 | Continuous |
4.0 | 23.9 | 0.3 | 7 | 0.01 | 28.2 | 40 | 6.0 | 3000 | Continuous |
6.0 | 23.9 | 0.6 | 14 | 0.01 | 45.7 | 100 | 7.1 | 4530 | Continuous |
8.0 | 23.9 | 1.1 | 26 | 0.02 | 58.7 | 180 | 6.8 | 6040 | Continuous |
10.0 | 23.8 | 1.9 | 45 | 0.04 | 66.9 | 290 | 6.5 | 7520 | Continuous |
12.0 | 23.8 | 3.0 | 71 | 0.06 | 74.0 | 410 | 5.8 | 8970 | Continuous |
14.0 | 23.7 | 4.5 | 107 | 0.08 | 78.1 | 570 | 5.3 | 10370 | Continuous |
16.0 | 23.6 | 6.5 | 153 | 0.10 | 79.5 | 740 | 4.8 | 11710 | Continuous |
18.0 | 23.5 | 8.9 | 210 | 0.13 | 81.3 | 930 | 4.4 | 12950 | Continuous |
20.0 | 23.4 | 11.7 | 274 | 0.15 | 81.9 | 1110 | 4.0 | 14100 | Continuous |
22.0 | 23.2 | 14.9 | 347 | 0.18 | 82.3 | 1300 | 3.7 | 15130 | Continuous |
24.0 | 23.2 | 16.1 | 373 | 0.19 | 82.5 | 1370 | 3.7 | 15430 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.