Vertiq 40-06 770Kv

10x5R

Philadelphia, PA USA | 15m | 2024-06-26 | 24.6 C | 29.72 in Hg | 50.2% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
2.0 23.9 0.1 3 1460 0.00 20.9 20 6.8 Continuous
4.0 23.9 0.4 10 2980 0.02 49.5 90 9.2 Continuous
6.0 23.9 1.0 24 4470 0.03 66.5 210 8.7 Continuous
8.0 23.9 2.1 49 5900 0.06 76.0 390 7.9 Continuous
10.0 23.9 3.7 87 7260 0.09 81.3 580 6.6 Continuous
12.0 23.8 5.8 139 8510 0.13 84.0 810 5.8 Continuous
14.0 23.7 8.6 204 9630 0.17 84.7 1060 5.2 Continuous
16.0 23.7 11.7 277 10610 0.21 84.8 1290 4.7 Continuous
18.0 23.6 15.3 360 11470 0.25 84.1 1510 4.2 Continuous
20.0 23.5 19.1 449 12210 0.29 83.1 1720 3.8 Continuous
22.0 23.3 23.4 546 12860 0.33 81.8 1920 3.5 Continuous
24.0 23.3 24.1 562 12930 0.34 81.3 1950 3.5 Continuous*

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous" region should not cause motor or ESC overheating when using the Default or Pro Kits.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the Performance Kit.
Performance in the "Continuous*" region is classified as intermittent when not using the Performance Kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.