Vertiq 40-06 370Kv
T-Motor P17x5.8R
Philadelphia, PA USA | 15m | 2023-05-30 | 23.4 C | 30.16 in Hg | 38.3 %
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Torque (Nm) | Thrust (g) | Input Power (W) | Speed (RPM) | Motor-Controller Efficiency (%) | Propulsion Efficiency (g/W) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
2.0 | 23.9 | 0.1 | 0.01 | 30 | 2 | 700 | 40.2 | 18.9 | Continuous |
4.0 | 23.9 | 0.3 | 0.03 | 130 | 6 | 1390 | 74.9 | 20.2 | Continuous |
6.0 | 23.9 | 0.8 | 0.07 | 290 | 18 | 2030 | 84.2 | 16.0 | Continuous |
8.0 | 23.9 | 1.6 | 0.12 | 500 | 38 | 2610 | 86.0 | 13.1 | Continuous |
10.0 | 23.8 | 2.8 | 0.17 | 730 | 66 | 3130 | 85.4 | 11.0 | Continuous |
12.0 | 23.8 | 4.3 | 0.23 | 990 | 103 | 3580 | 83.8 | 9.7 | Continuous |
14.0 | 23.7 | 6.1 | 0.28 | 1240 | 145 | 3970 | 81.4 | 8.5 | Continuous |
16.0 | 23.6 | 8.2 | 0.33 | 1460 | 193 | 4320 | 78.4 | 7.6 | Continuous |
18.0 | 23.5 | 10.6 | 0.38 | 1680 | 250 | 4610 | 74.4 | 6.7 | Intermittent |
20.0 | 23.4 | 13.5 | 0.43 | 1890 | 315 | 4870 | 69.6 | 6.0 | Intermittent |
22.0 | 23.2 | 16.9 | 0.47 | 2080 | 392 | 5080 | 63.9 | 5.3 | Intermittent |
24.0 | 23.2 | 18.2 | 0.48 | 2100 | 421 | 5120 | 60.7 | 5.0 | Intermittent |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.