Vertiq 23-14 920Kv

P12x4 11V CW

Philadelphia, PA USA | 15m | 2023-09-15 | 23.5 C | 30.02 in Hg | 47.6% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 11.0 0.1 1 882 0.00 36.7 20 25.6 Continuous
2.0 11.0 0.3 3 1748 0.01 64.2 70 21.1 Continuous
3.0 11.0 0.8 9 2577 0.03 75.6 150 16.4 Continuous
4.0 11.0 1.8 19 3369 0.04 79.6 270 13.9 Continuous
5.0 10.9 3.2 35 4122 0.07 80.9 410 11.8 Continuous
6.0 10.9 5.2 56 4833 0.09 80.7 570 10.2 Continuous
7.0 10.8 7.7 83 5488 0.12 79.8 740 8.9 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.