Vertiq 23-14 920Kv
P12x4 11V CW
Philadelphia, PA USA | 15m | 2023-09-15 | 23.5 C | 30.02 in Hg | 47.6% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Speed (RPM) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
1.0 | 11.0 | 0.1 | 1 | 882 | 0.00 | 36.7 | 20 | 25.6 | Continuous |
2.0 | 11.0 | 0.3 | 3 | 1748 | 0.01 | 64.2 | 70 | 21.1 | Continuous |
3.0 | 11.0 | 0.8 | 9 | 2577 | 0.03 | 75.6 | 150 | 16.4 | Continuous |
4.0 | 11.0 | 1.8 | 19 | 3369 | 0.04 | 79.6 | 270 | 13.9 | Continuous |
5.0 | 10.9 | 3.2 | 35 | 4122 | 0.07 | 80.9 | 410 | 11.8 | Continuous |
6.0 | 10.9 | 5.2 | 56 | 4833 | 0.09 | 80.7 | 570 | 10.2 | Continuous |
7.0 | 10.8 | 7.7 | 83 | 5488 | 0.12 | 79.8 | 740 | 8.9 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.