Vertiq 23-14 920Kv

HQ 9x5 16V

Philadelphia, PA USA | 15m | 2023-09-14 | 23.9 C | 30.04 in Hg | 53.5% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 16.0 0.0 1 898 0.00 13.0 0 0.0 Continuous
2.0 16.0 0.1 2 1803 0.00 35.3 20 9.3 Continuous
3.0 16.0 0.3 5 2696 0.01 52.6 50 10.2 Continuous
4.0 16.0 0.6 9 3583 0.02 63.5 100 10.6 Continuous
5.0 16.0 1.0 16 4449 0.02 70.3 170 10.6 Continuous
6.0 16.0 1.6 25 5302 0.03 74.8 250 9.9 Continuous
7.0 15.9 2.3 37 6132 0.05 78.0 340 9.1 Continuous
8.0 15.9 3.3 52 6940 0.06 79.9 440 8.4 Continuous
9.0 15.9 4.5 71 7722 0.07 81.1 550 7.8 Continuous
10.0 15.8 5.9 93 8448 0.09 81.5 670 7.2 Continuous
11.0 15.8 7.6 121 9184 0.10 81.9 800 6.6 Continuous
12.0 15.7 9.5 150 9839 0.12 81.3 920 6.2 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.