Vertiq 23-14 920Kv

HQ 8x5 18V

Philadelphia, PA USA | 15m | 2023-09-14 | 23.8 C | 30.05 in Hg | 53.7% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 18.0 0.0 1 903 0.00 10.3 0 0.0 Continuous
2.0 18.0 0.1 2 1817 0.00 28.6 10 4.9 Continuous
3.0 18.0 0.2 4 2725 0.01 45.2 40 9.2 Continuous
4.0 18.0 0.4 8 3627 0.01 56.4 80 10.0 Continuous
5.0 18.0 0.7 13 4517 0.02 64.6 120 9.1 Continuous
6.0 18.0 1.1 20 5404 0.02 70.1 190 9.5 Continuous
7.0 18.0 1.6 29 6269 0.03 74.3 250 8.6 Continuous
8.0 17.9 2.2 40 7115 0.04 77.4 330 8.2 Continuous
9.0 17.9 3.0 54 7948 0.05 79.6 410 7.6 Continuous
10.0 17.9 4.0 71 8740 0.06 80.9 500 7.0 Continuous
11.0 17.9 5.1 91 9510 0.07 81.6 590 6.5 Continuous
12.0 17.8 6.4 113 10211 0.09 81.9 690 6.1 Continuous
13.0 17.8 7.9 140 10948 0.10 82.1 800 5.7 Continuous
14.0 17.7 9.6 169 11658 0.11 81.9 900 5.3 Continuous
15.0 17.7 11.5 203 12347 0.13 81.5 1010 5.0 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.