Vertiq 23-14 920Kv
Gemfan 8060x3 14V
Philadelphia, PA USA | 15m | 2023-09-14 | 23.7 C | 30.04 in Hg | 59.0% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Speed (RPM) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
1.0 | 14.0 | 0.0 | 1 | 889 | 0.00 | 20.4 | 10 | 14.5 | Continuous |
2.0 | 14.0 | 0.2 | 2 | 1782 | 0.01 | 47.6 | 30 | 12.4 | Continuous |
3.0 | 14.0 | 0.4 | 6 | 2658 | 0.01 | 65.0 | 60 | 10.0 | Continuous |
4.0 | 14.0 | 0.9 | 12 | 3513 | 0.03 | 74.6 | 120 | 9.7 | Continuous |
5.0 | 14.0 | 1.6 | 22 | 4354 | 0.04 | 79.9 | 190 | 8.7 | Continuous |
6.0 | 14.0 | 2.5 | 35 | 5169 | 0.05 | 83.1 | 270 | 7.8 | Continuous |
7.0 | 13.9 | 3.7 | 52 | 5950 | 0.07 | 84.6 | 360 | 7.0 | Continuous |
8.0 | 13.9 | 5.3 | 73 | 6711 | 0.09 | 85.5 | 480 | 6.6 | Continuous |
9.0 | 13.8 | 7.2 | 99 | 7422 | 0.11 | 85.6 | 600 | 6.1 | Continuous |
10.0 | 13.8 | 9.4 | 129 | 8101 | 0.13 | 85.2 | 720 | 5.6 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.