Vertiq 23-14 920Kv

Flash 7042 18V

Philadelphia, PA USA | 15m | 2023-09-14 | 23.4 C | 30.05 in Hg | 60.0% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 18.0 0.0 1 897 0.00 7.1 0 0.0 Continuous
2.0 18.0 0.1 2 1814 0.00 12.8 0 0.0 Continuous
3.0 18.0 0.2 4 2727 0.00 31.5 20 4.9 Continuous
4.0 18.0 0.4 7 3634 0.01 46.0 40 5.4 Continuous
5.0 18.0 0.7 12 4534 0.01 56.1 70 5.8 Continuous
6.0 18.0 1.0 19 5432 0.02 63.5 110 5.9 Continuous
7.0 18.0 1.5 27 6310 0.03 69.0 160 5.9 Continuous
8.0 18.0 2.1 37 7199 0.04 73.5 220 5.9 Continuous
9.0 17.9 2.7 49 8056 0.04 76.9 300 6.1 Continuous
10.0 17.9 3.6 64 8892 0.06 80.1 370 5.7 Continuous
11.0 17.9 4.5 81 9695 0.07 81.9 440 5.4 Continuous
12.0 17.8 5.7 102 10456 0.08 83.4 530 5.2 Continuous
13.0 17.8 7.1 125 11225 0.09 84.4 610 4.9 Continuous
14.0 17.7 8.5 151 11986 0.10 85.0 700 4.6 Continuous
15.0 17.7 10.2 181 12727 0.12 85.3 790 4.4 Continuous
16.0 17.6 12.2 214 13428 0.13 85.1 890 4.2 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.