Vertiq 23-14 920Kv

APC 9x4.5 18V

Philadelphia PA USA | 15m | 2023-06-14 | 25.6 C | 29.55 in Hg | 47.4% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Torque (Nm) Thrust (g) Input Power (W) Speed (RPM) Motor-Controller Efficiency (%) Propulsion Efficiency (g/W) State of Operation
1.0 18.0 0.0 0.00 0 1 900 10.9 0.0 Continuous
2.0 18.0 0.1 0.00 20 2 1810 29.5 9.7 Continuous
3.0 18.0 0.2 0.01 40 4 2710 45.5 9.1 Continuous
4.0 18.0 0.5 0.01 70 8 3610 57.8 8.5 Continuous
5.0 18.0 0.8 0.02 110 14 4490 66.9 7.9 Continuous
6.0 18.0 1.2 0.03 160 22 5360 73.2 7.3 Continuous
7.0 17.9 1.8 0.04 220 32 6220 77.8 6.8 Continuous
8.0 17.9 2.5 0.05 290 46 7060 80.8 6.4 Continuous
9.0 17.9 3.5 0.06 360 63 7860 83.0 5.7 Continuous
10.0 17.9 4.7 0.08 440 84 8630 84.4 5.2 Continuous
11.0 17.9 6.1 0.10 530 109 9360 85.1 4.8 Continuous
12.0 17.8 7.8 0.11 610 139 10040 85.2 4.4 Continuous
13.0 17.8 9.9 0.13 710 176 10700 84.9 4.0 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.