Vertiq 23-14 920Kv
APC 9x4.5 16V
Philadelphia, PA USA | 15m | 2023-09-14 | 23.8 C | 30.04 in Hg | 52.7% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Speed (RPM) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
1.0 | 16.0 | 0.0 | 1 | 897 | 0.00 | 14.4 | 0 | 0.0 | Continuous |
2.0 | 16.0 | 0.1 | 2 | 1811 | 0.00 | 34.9 | 10 | 4.9 | Continuous |
3.0 | 16.0 | 0.3 | 4 | 2716 | 0.01 | 50.8 | 40 | 9.0 | Continuous |
4.0 | 16.0 | 0.5 | 9 | 3614 | 0.01 | 61.6 | 70 | 8.2 | Continuous |
5.0 | 16.0 | 0.9 | 14 | 4503 | 0.02 | 70.3 | 110 | 7.6 | Continuous |
6.0 | 16.0 | 1.4 | 23 | 5371 | 0.03 | 76.3 | 160 | 6.9 | Continuous |
7.0 | 16.0 | 2.2 | 35 | 6215 | 0.04 | 80.7 | 220 | 6.3 | Continuous |
8.0 | 16.0 | 3.1 | 50 | 7035 | 0.06 | 83.6 | 290 | 5.8 | Continuous |
9.0 | 15.9 | 4.4 | 69 | 7806 | 0.07 | 85.2 | 370 | 5.3 | Continuous |
10.0 | 15.9 | 5.9 | 93 | 8540 | 0.09 | 86.1 | 450 | 4.8 | Continuous |
11.0 | 15.8 | 7.7 | 122 | 9303 | 0.11 | 86.6 | 540 | 4.4 | Continuous |
12.0 | 15.8 | 9.9 | 156 | 9893 | 0.13 | 86.0 | 630 | 4.0 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.