Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 14.0 0.0 1 895 0.00 17.5 0 0.0 Continuous
2.0 14.0 0.2 2 1792 0.01 42.9 30 13.0 Continuous
3.0 14.0 0.4 6 2674 0.01 60.2 70 12.6 Continuous
4.0 14.0 0.8 11 3539 0.02 70.2 130 11.6 Continuous
5.0 14.0 1.4 20 4380 0.03 75.8 220 11.1 Continuous
6.0 14.0 2.3 32 5197 0.05 79.0 320 10.1 Continuous
7.0 13.9 3.4 48 5988 0.06 80.7 430 9.1 Continuous
8.0 13.9 4.8 67 6738 0.08 81.4 550 8.2 Continuous
9.0 13.9 6.6 92 7446 0.10 81.5 690 7.5 Continuous
10.0 13.8 8.7 121 8120 0.12 81.1 820 6.8 Continuous
11.0 13.8 11.2 154 8773 0.13 80.3 960 6.2 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.