Vertiq 23-14 920Kv
APC 10x5 14V
Philadelphia, PA USA | 15m | 2023-09-14 | 23.9 C | 30.04 in Hg | 52.5% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Speed (RPM) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
1.0 | 14.0 | 0.0 | 1 | 895 | 0.00 | 17.5 | 0 | 0.0 | Continuous |
2.0 | 14.0 | 0.2 | 2 | 1792 | 0.01 | 42.9 | 30 | 13.0 | Continuous |
3.0 | 14.0 | 0.4 | 6 | 2674 | 0.01 | 60.2 | 70 | 12.6 | Continuous |
4.0 | 14.0 | 0.8 | 11 | 3539 | 0.02 | 70.2 | 130 | 11.6 | Continuous |
5.0 | 14.0 | 1.4 | 20 | 4380 | 0.03 | 75.8 | 220 | 11.1 | Continuous |
6.0 | 14.0 | 2.3 | 32 | 5197 | 0.05 | 79.0 | 320 | 10.1 | Continuous |
7.0 | 13.9 | 3.4 | 48 | 5988 | 0.06 | 80.7 | 430 | 9.1 | Continuous |
8.0 | 13.9 | 4.8 | 67 | 6738 | 0.08 | 81.4 | 550 | 8.2 | Continuous |
9.0 | 13.9 | 6.6 | 92 | 7446 | 0.10 | 81.5 | 690 | 7.5 | Continuous |
10.0 | 13.8 | 8.7 | 121 | 8120 | 0.12 | 81.1 | 820 | 6.8 | Continuous |
11.0 | 13.8 | 11.2 | 154 | 8773 | 0.13 | 80.3 | 960 | 6.2 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.