Vertiq 23-14 920Kv

APC 10x4.5 12V

Philadelphia, PA USA | 15m | 2023-09-14 | 24.2 C | 30.04 in Hg | 54.7% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 12.0 0.1 1 885 0.00 32.7 10 13.4 Continuous
2.0 12.0 0.3 3 1756 0.01 61.2 50 15.9 Continuous
3.0 12.0 0.7 8 2596 0.02 73.4 120 14.3 Continuous
4.0 12.0 1.5 17 3406 0.04 78.6 220 12.7 Continuous
5.0 12.0 2.6 31 4188 0.06 80.8 330 10.6 Continuous
6.0 11.9 4.2 50 4923 0.08 81.2 470 9.3 Continuous
7.0 11.9 6.3 75 5617 0.10 80.7 620 8.3 Continuous
8.0 11.8 8.9 105 6232 0.13 79.5 780 7.4 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.