Vertiq 23-14 920Kv
Vertiq UPF-23-12 11V
Philadelphia, PA USA | 15m | 2023-09-15 | 23.9 C | 30.01 in Hg | 48.9% Humidity
Commanded Voltage (V) | Supply Voltage (V) | Supply Current (A) | Input Power (W) | Speed (RPM) | Torque (Nm) | Motor-Controller Efficiency (%) | Thrust (g) | Propulsion Efficiency (g/W) | State of Operation |
---|---|---|---|---|---|---|---|---|---|
1.0 | 11.0 | 0.1 | 1 | 880 | 0.00 | 37.1 | 20 | 24.4 | Continuous |
2.0 | 11.0 | 0.3 | 4 | 1740 | 0.01 | 64.7 | 70 | 19.8 | Continuous |
3.0 | 11.0 | 0.9 | 10 | 2560 | 0.03 | 75.2 | 160 | 16.4 | Continuous |
4.0 | 11.0 | 1.9 | 21 | 3342 | 0.05 | 79.1 | 280 | 13.5 | Continuous |
5.0 | 10.9 | 3.4 | 37 | 4086 | 0.07 | 80.3 | 410 | 11.1 | Continuous |
6.0 | 10.9 | 5.5 | 59 | 4789 | 0.09 | 80.1 | 550 | 9.3 | Continuous |
7.0 | 10.8 | 8.1 | 88 | 5421 | 0.12 | 78.9 | 700 | 8.0 | Continuous |
All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.