Vertiq 23-06 2200Kv

Vertiq UPF-23-12 18V

Philadelphia, PA USA | 15m | 2023-03-08 | 27.2 C | 30.18 in Hg | 15.8% Humidity

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Torque (Nm) Thrust (g) Input Power (W) Speed (RPM) Motor-Controller Efficiency (%) Propulsion Efficiency (g/W) State of Operation
0.25 18.0 0.0 0.00 0 0 470 22.2 0.0 Continuous
0.50 18.0 0.0 0.00 20 1 940 48.7 29.6 Continuous
0.75 18.0 0.1 0.01 40 2 1380 66.3 25.5 Continuous
1.00 18.0 0.2 0.01 60 3 1800 71.5 18.7 Continuous
1.25 18.0 0.3 0.02 100 6 2200 74.0 17.5 Continuous
1.50 18.0 0.5 0.03 130 9 2570 75.2 14.4 Continuous
1.75 18.0 0.8 0.03 180 14 2920 74.4 13.2 Continuous
2.00 18.0 1.1 0.04 230 19 3250 73.3 12.0 Continuous
2.25 17.9 1.4 0.05 270 26 3550 71.7 10.5 Continuous
2.50 17.9 1.9 0.06 320 33 3840 71.7 9.6 Continuous
2.75 17.9 2.3 0.07 370 42 4100 67.6 8.8 Continuous
3.00 17.8 2.9 0.15 390 51 4350 130.3 7.6 Continuous
3.25 17.8 3.4 0.16 430 61 4570 125.9 7.0 Continuous

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.