Vertiq 23-06 2200Kv

APC6x3R 18V

Philadelphia, PA USA | Altitude:15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nmm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1 17.8 0.1 1 2091 0.57 12.1% 5 4.9 Continuous
2 17.8 0.2 3 4212 2.21 29.4% 20 6.1 Continuous
3 17.8 0.4 8 6340 5.04 43.2% 46 5.9 Continuous
4 17.8 0.8 15 8396 9.47 56.2% 81 5.5 Continuous
5 17.8 1.4 25 10421 14.76 63.9% 128 5.1 Continuous
6 17.8 2.2 40 12333 21.06 68.4% 183 4.6 Continuous
7 17.7 3.4 61 14215 29.17 71.3% 250 4.1 Continuous
8 17.7 4.9 88 15989 38.61 73.8% 323 3.7 Continuous
9 17.7 6.9 121 17644 49.29 75.0% 401 3.3 Continuous
10 17.6 9.4 165 19229 61.84 75.6% 489 3 Continuous
11 17.5 12.1 213 20645 74.61 75.7% 571 2.7 Intermittent
12 17.5 15.4 270 21951 88.58 75.5% 656 2.4 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.