Vertiq 23-06 2200Kv

APC5x4R 18V

Philadelphia, PA USA | Altitude:15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nmm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 17.8 0.1 1 2105 0.45 9.7% 4 4.0 Continuous
2.0 17.8 0.2 3 4244 1.90 26.8% 16 5.0 Continuous
3.0 17.8 0.4 7 6378 4.30 40.2% 35 4.9 Continuous
4.0 17.8 0.8 14 8466 8.06 52.7% 61 4.5 Continuous
5.0 17.8 1.3 23 10495 12.45 60.3% 94 4.2 Continuous
6.0 17.8 2.0 36 12461 17.96 65.8% 135 3.8 Continuous
7.0 17.7 3.0 53 14376 24.28 69.0% 182 3.4 Continuous
8.0 17.7 4.3 76 16195 31.87 71.4% 237 3.1 Continuous
9.0 17.7 5.8 103 17970 39.93 72.8% 294 2.8 Continuous
10.0 17.6 7.7 136 19672 48.97 74.1% 354 2.6 Continuous
11.0 17.6 10.0 176 21211 59.22 74.9% 418 2.4 Continuous
12.0 17.5 12.5 219 22665 69.16 74.9% 480 2.2 Intermittent
13.0 17.5 15.5 270 24055 80.37 74.9% 546 2.0 Intermittent
14.0 17.4 18.7 326 25513 90.35 74.1% 608 1.9 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.