Vertiq 23-06 2200Kv

APC5x3E 18V

Philadelphia, PA USA | Altitude:15m

Commanded Voltage (V) Supply Voltage (V) Supply Current (A) Input Power (W) Speed (RPM) Torque (Nmm) Motor-Controller Efficiency (%) Thrust (g) Propulsion Efficiency (g/W) State of Operation
1.0 17.8 0.1 1 2109 0.31 7.1% 3 2.9 Continuous
2.0 17.8 0.2 3 4263 1.36 20.8% 13 4.4 Continuous
3.0 17.8 0.4 6 6421 3.06 33.0% 32 5.1 Continuous
4.0 17.8 0.6 11 8549 5.71 45.2% 57 5.1 Continuous
5.0 17.8 1.0 18 10663 8.48 52.8% 92 5.1 Continuous
6.0 17.8 1.5 27 12713 11.94 59.1% 133 4.9 Continuous
7.0 17.8 2.2 39 14702 16.03 63.8% 180 4.7 Continuous
8.0 17.7 3.0 53 16633 20.56 67.0% 234 4.4 Continuous
9.0 17.7 4.1 72 18525 25.85 69.5% 294 4.1 Continuous
10.0 17.7 5.3 94 20290 31.31 71.1% 355 3.8 Continuous
11.0 17.7 6.8 119 21961 37.70 72.7% 423 3.5 Continuous
12.0 17.6 8.4 148 23596 43.98 73.2% 486 3.3 Continuous
13.0 17.6 10.4 184 25105 51.72 74.1% 553 3.0 Continuous
14.0 17.5 12.9 226 26619 60.17 74.4% 620 2.7 Continuous
15.0 17.5 15.6 273 28097 68.53 73.9% 681 2.5 Intermittent
16.0 17.4 19.2 333 29772 79.58 74.4% 759 2.3 Intermittent

All data is rated for normal temperature and pressure (NTP).
Performance is degraded at higher temperatures and lower pressures.
Performance in the "Continuous*" region should not cause motor or ESC overheating when using the performance kit.
Performance in the "Continuous*" region is classified as intermittent when not using the performance kit.
Performance in the "Intermittent" region will cause overheating with prolonged use.